The Complete Guide to PCB Vias: Through‑Hole, Blind, Buried, and Microvias

If you‘ve ever looked closely at a multi‑layer PCB, you’ve noticed the small copper‑plated holes. Those are vias. They might look simple, but choosing the wrong type or size can hurt your signal integrity — and double your manufacturing cost.
This article breaks down the four common via types (through‑hole, blind, buried, microvia) from a practical hardware engineering perspective. You‘ll learn how they work, when to use each one, and how to make cost‑effective design decisions.
1. What Is a Via and Why Does It Matter?
A via is a plated hole that creates an electrical connection between different copper layers of a PCB. Think of it as a small “elevator shaft” that carries signals and power up and down through the board.
For multi‑layer PCBs, vias are essential. Without them, traces on different layers would be isolated. In high‑density, high‑speed designs, the via structure can make or break the entire board.
2. The Four Via Types Explained
2.1 Through‑Hole Via
Definition – Drilled from top to bottom through the whole board and then plated with copper. You can see the hole on both sides.
| Attribute | Value |
|---|---|
| Cost | Baseline (cheapest) |
| Typical minimum diameter | 0.3 mm (mechanical drill) |
| Process maturity | Very high |
| Best for | 2‑6 layer boards, most prototypes and small‑medium volumes |
Pros
Mature technology, available at almost any fab
Lowest cost
Simple design, supported by all EDA tools
Cons
Occupies space on every layer (even where it isn’t needed)
Drill size is relatively large – not suitable for ultra‑dense layouts
When to use – 80% of designs work perfectly with through‑hole vias. Make them your default choice unless you have a clear reason to upgrade.
2.2 Blind Via
Definition – Starts on an outer layer (top or bottom) and stops at an inner layer. Does not go through the whole board. You see the hole on only one side.
| Attribute | Value |
|---|---|
| Cost | +30‑50% vs. through‑hole |
| Typical minimum diameter | 0.2‑0.25 mm |
| Process | Sequential lamination + laser/mechanical drilling |
| Best for | High‑density HDI boards, smartphones, wearables |
Pros
Saves routing space on inner layers
Allows more components on the opposite side
Cons
Requires sequential lamination → longer lead time
Significantly higher cost
More complex design rules
When to use – Only when an outer layer must connect to an inner layer and using a through‑hole via would ruin your routing density.
2.3 Buried Via
Definition – Connects two or more inner layers but does not reach either outer layer. You see the hole on neither side.
| Attribute | Value |
|---|---|
| Cost | +50‑100% vs. through‑hole |
| Typical minimum diameter | 0.2‑0.25 mm |
| Process | Multiple sequential laminations, complex |
| Best for | 12+ layer high‑end servers, communication backplanes |
Pros
Uses zero outer‑layer space
Enables extremely dense inner‑layer connections
Cons
Expensive and slow to manufacture
Difficult to design, test, and rework
When to use – Almost exclusively in large, high‑layer‑count products. Not recommended for prototypes or small‑batch production.
2.4 Microvia
Definition – A very small hole (typically ≤ 0.1 mm) drilled with a laser, used in HDI (high‑density interconnect) boards. Microvias are usually implemented as blind vias and can be stacked or staggered.
| Attribute | Value |
|---|---|
| Cost | 2‑5× vs. through‑hole |
| Typical diameter | 0.075‑0.1 mm |
| Process | Laser drilling + sequential lamination |
| Best for | 0.4 mm pitch BGAs and smaller, smartphones, advanced wearables |
Pros
Saves a huge amount of board space
Allows direct connection from BGA pads to inner layers without using surface routing channels
Cons
Very expensive
Strict design rules (e.g., stacked microvias require filled and plated vias)
Significantly extended lead time
When to use – Only when component density leaves you no other option (e.g., 0.35 mm pitch BGA).
3. Key Via Parameters
Beyond the type, these parameters also affect performance and cost.
| Parameter | Meaning | Recommended Value |
|---|---|---|
| Hole size | Drilled diameter | ≥0.3 mm (through‑hole), ≤0.1 mm (microvia) |
| Pad diameter | Outer copper ring diameter | Usually hole + 0.25‑0.3 mm |
| Annular ring | Copper width from hole edge to pad inner edge | Outer layers ≥0.25 mm, inner layers ≥0.15 mm |
| Aspect ratio | Board thickness ÷ hole diameter | ≤10:1 (standard), ≤8:1 (more reliable) |
Important – If the aspect ratio is too high, the plating solution may not reach the centre of the hole, leading to an open circuit. For a standard 1.6 mm thick board, the minimum reliable through‑hole diameter is about 0.2 mm, but 0.3 mm is strongly recommended for good yield.
4. Cost Comparison (Realistic Numbers)
Based on a small‑batch order of 100 pieces, 4‑layer board (1.6 mm thick, excluding microvia special pricing):
| Via Type | Relative Cost (vs. through‑hole) | Example per‑board cost |
|---|---|---|
| Through‑hole | 1.0× | ¥15 / $2.10 |
| Blind (1‑step) | ~1.5× | ¥22 / $3.10 |
| Buried | ~1.8× | ¥27 / $3.80 |
| Microvia (laser) | ~3× | ¥45 / $6.30 |
| Stacked microvia (2‑step) | ~5× | ¥75 / $10.50 |
The exact numbers depend on the fab and volume, but the cost ratios are consistent.
5. When Should You Move Beyond Through‑Hole Vias?
| Scenario | Recommended Via Strategy |
|---|---|
| Routing is tight but BGA pitch ≥0.5 mm | Try shrinking the via pad (within DFM limits) or add more layers |
| 0.4 mm pitch BGA | Consider 1‑step blind vias (outer layer to second layer) |
| 0.35 mm pitch BGA or smaller | Must use microvias, possibly stacked |
| High‑speed signal needs very short stub | Backdrilling is cheaper than blind vias – use it first |
| Dense inner‑layer connections | Buried vias → but only for 13+ layers |
Backdrill tip – For high‑speed signals (>10 Gbps), you can backdrill a through‑hole via to remove the unused stub. This is much cheaper than switching to blind vias.
6. Common Via Design Mistakes
Using the same size for all vias
- Signal vias can be 0.3 mm; power vias often need 0.4‑0.5 mm or multiple parallel vias.
Ignoring current carrying capability
- A 0.3 mm via with 1 oz plating carries about 1‑1.5 A. For 3 A, use three vias or a larger one.
Placing vias too close together
- Keep the edge‑to‑edge distance at least 0.3 mm (or follow your manufacturer‘s minimum spacing). Too close can cause shorts or warpage.
Forgetting thermal relief on power vias
- If a via connects to a large copper pour, use thermal relief spokes; otherwise soldering becomes difficult.
Chasing microvias unnecessarily
- On a 0.5 mm pitch BGA, you can often fan out with through‑hole vias by using proper design rules (e.g., dog‑bone fanout). Microvias are not needed.
7. Decision Quick‑Reference Table
| You need... | First choice | Alternative |
|---|---|---|
| Cheapest, most reliable connection | Through‑hole | — |
| Smaller board but BGA is coarse (≥0.5 mm) | Add layers | — |
| 0.4 mm BGA fanout | Blind via | Shrink through‑hole pad (ask DFM) |
| 0.35 mm BGA | Microvia | — |
| Lower stub for high‑speed signals | Backdrilled through‑hole | Blind via (more expensive) |
8. Final Summary
For more than 80% of PCB projects, through‑hole vias are sufficient. They are cheap, reliable, and well understood. Use them as your default.
Blind, buried, and microvias are powerful tools, but each time you step up to a more advanced type, you add significant cost and manufacturing complexity. Before you commit, ask yourself three questions:
Can I really not solve this by adding a couple of layers?
Have I checked the manufacturer’s minimum through‑hole fan‑out rules?
Does the production volume justify the extra cost?
Only when all answers are “yes” should you move to blind or microvias.
This article is based on real manufacturing experience from AnyPCBA. We offer free DFM reviews to help hardware engineers avoid via‑related manufacturing issues. Need help? Reach out through our website.
About the author
- PCB manufacturing professional with 10+ years of experience. Working at AnyPCBA, serving global clients with PCB fabrication & assembly. DM for inquiries. https://www.anypcba.com/
Comments
Join the discussionNo comments yet. Be the first to comment.